| Input Voltage Range | | 14 | 110 | 160 | VDC |
| | | | | |
| Output Accuracy | Nominal Input Voltage, 10% - 100% Load | | | ±2.0 | % |
| Line Regulation | Input Voltage variation from low to high | | | ±0.5 | % |
| Load Regulation | Nominal Input Voltage, 10% - 100% Load | | ±0.5 | ±1 | mSec |
| Short Circuit Protection | | Continuous (Autorecovery) | | | |
| Isolation Voltage | 60 seconds, leakage current <5 mA (Input - Output) | 3,000 | | | VDC |
| 60 seconds, leakage current <5 mA (Input/Output - Case) | 2,100 | | | VDC |
| Operating Temp Range | | -40°C | | +105°C | °C |
| MTBF | IEC 61709 @ 25°C | | 1000 | | kHrs |
| Shock & Vibration | | IEC/EN61373 Class B | | | |
| Case Size | In | 2.28 x 1.449 x 0.50 | | | |
| mm | 57.90 x 36.80 x 12.70 | | | |
| | | | | |
| Case Size With Heatsink(-F) | In | 2.441 x 2.205 x 0.571 | | | |
| mm | 62.00 x 56.00 x 14.50 | | | |
| | | | | |
| Case Size With Heatsink(-H) | In | 2.28 x 1.449 x 1.00 | | | |
| mm | 57.90 x 36.80 x 25.40 | | | |