| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 92 | 264 | VAC | ||
| 127 | 370 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 40 | A Pk | ||
| 230 VAC | 75 | ||||
| Line Regulation | At Rated Load | ±0.5 | % | ||
| Load Regulation | 0% to 100% | ±1.0 | % | ||
| Hold-Up Time | Air Cooling | 12 | 14 | mSec | |
| 20.5 CFM | 6 | 8 | |||
| Isolation Voltage | 4000 | VAC | |||
| Operating Temp Range | -40 | +70 | °C | ||
| MTBF | 300 | kHrs | |||
| Case Size | |||||
| in | 5.00 x 3.00 x 1.00 | ||||
| mm | 127.00 x 76.20 x 25.40 | ||||
| Package Type | Open Frame | ||||
| Safety Class | Class I (with PE connected), Class II (without PE) | ||||
| Safety Standards | UL/cUL 62368-1 Recognition (UL certificate) | ||||
| UL/cUL 60601-1 Recognition (UL certificate) | |||||
| EMI/EMS Standards | EN 55032 B |
| Model No. | Output V | Output I |
|---|---|---|
| MPO-350C-12 | 12 VDC | 25.0 A |
| MPO-350C-15 | 15 VDC | 21.67 A |
| MPO-350C-18 | 18 VDC | 18.0 A |
| MPO-350C-19 | 19 VDC | 17.10 A |
| MPO-350C-24 | 24 VDC | 14.60 A |
| MPO-350C-27 | 27 VDC | 13.0 A |
| MPO-350C-36 | 36 VDC | 9.73 A |
| MPO-350C-48 | 48 VDC | 7.30 A |
| MPO-350C-54 | 54 VDC | 6.50 A |