| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 264 | VAC | ||
| 120 | 370 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 50 | A Pk | ||
| 230 VAC | 85 | ||||
| Line Regulation | Vin = Min to Max | ±1.0 | % | ||
| Load Regulation | 10% to 100% | ±1.0 | % | ||
| Hold-Up Time | 115 VAC, 90% Vout | 8.0 | mSec | ||
| Isolation Voltage | 4000 | VAC | |||
| Operating Temp Range | -30 | +70 | °C | ||
| MTBF | 400 | kHrs | |||
| Case Size | |||||
| in | 3.59 x 2.15 x 1.36 | ||||
| mm | 91.19 x 54.61 x 34.60 | ||||
| Package Type | Open Frame | ||||
| Safety Class | EN 55032 Class B | ||||
| Safety Standards | UL/cUL 62368-1 Recognition (UL certificate) | ||||
| EMI/EMS Standards | EN 55032 / EN 55035 |
| Model No. | Output V | Output I |
|---|---|---|
| MPO-130SAR-12 | 12 VDC | 10.833 A |
| MPO-130SAR-24 | 24 VDC | 5.417 A |
| MPO-130SAR-48 | 48 VDC | 2.708 A |