| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 85 | 305 | VAC | ||
| 100 | 430 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 30 | A | ||
| 230 VAC | 60 | ||||
| Line Regulation | Full Load | ±1 | % | ||
| Load Regulation | 0 to 100% Load | ±1.5 | % | ||
| Hold-Up Time | 115 VAC | 8 | mSec | ||
| 230 VAC | 65 | ||||
| Isolation Voltage | 4,200 | VAC | |||
| Operating Temp Range | -40 | +85 | °C | ||
| MTBF | >500 | kHrs | |||
| Case Size | Without Chassis Mount | 2.756 x 1.890 x 1.063 | |||
| 70.0 x 48.0 x 27.0 | |||||
| With Chassis Mount | 3.783 x 2.126 x 1.398 | ||||
| 96.10 x 54.0 x 35.50 | |||||
| Package Type | Encapsulated Module | ||||
| Safety Class | |||||
| Safety Standards | See Model Selection Guide | ||||
| EMI/EMC Standards | Meets EN 55032 B |
| Model No. | Output V | Output I |
|---|---|---|
| MPM-60C-05 | 5 VDC | 10 A |
| MPM-60C-12 | 12 VDC | 5 A |
| MPM-60C-15 | 15 VDC | 4 A |
| MPM-60C-24 | 24 VDC | 2.5 A |
| MPM-60C-48 | 48 VDC | 1.25 A |
| MPM-60C-55 | 55.5 VDC | 1.09 A |