| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 85 | 264 | VAC | ||
| 120 | 370 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 440 | Hz | ||
| Inrush Current | 115 VAC | 20 | A pk | ||
| 230 VAC | 40 | ||||
| Line Regulation | ±0.5 | % | |||
| Load Regulation | Single Output | ±0.5 | % | ||
| Dual Output | ±2.5 | ||||
| Hold-Up Time | 115 VAC, 60 Hz | 20 | mSec | ||
| 230 VAC, 50 Hz | 80 | ||||
| Isolation Voltage | 4,000 | VAC | |||
| Operating Temp Range | -40 | +80 | °C | ||
| MTBF | 400 | kHrs | |||
| Case Size | Without Chassis Mount | 2.91 x 2.15 x 0.77 | |||
| 74.0 x 63.50 x 19.50 | |||||
| With Chassis Mount | 3.39 x 2.15 | ||||
| Package Type | Encapsulated Module | ||||
| Safety Class | IEC 60536 Class II | ||||
| Safety Standards | UL 60950 | ||||
| EMI/EMC Standards | EN 60950 |
| Model No. | Output V | Output I |
|---|---|---|
| MPM-24MS-05xx | 5 | 3.0 A |
| MPM-24MS-09xx | 9 | 2.66 A |
| MPM-24MS-12xx | 12 | 2.0 A |
| MPM-24MS-15xx | 15 | 1.60 A |
| MPM-24MS-24xx | 24 | 1.0 A |
| MPM-24MD-12xx | ±12 | ±1.0 A |
| MPM24MD-15xx | ±15 | ±0.80 A |