| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | |||||
| AC Input | 85 | 264 | VAC | ||
| DC Input | 120 | 370 | VDC | ||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current(Cold Start) | 115 VAC | 3.7 | 20 | ||
| 230 VAC | 6.5 | 40 | A Pk | ||
| Power Factor(Full Load) | 115 VAC | 0.99 | --- | ||
| 230 VAC | 0.95 | ||||
| Line Regulation(At Rated Load) | Main Output | ±0.5 | % | ||
| Auxiliary Output | ±1.0 | ||||
| Load Regulation(0 - 100% Load) | Main Output | ±0.5 | % | ||
| Auxiliary Output | ±3.0 | ||||
| Hold-Up Time | Full Input Voltage | 12 | mSec | ||
| Isolation Voltage | 4000 | VAC | |||
| Operating Temp Range | -40 | +70 | °C | ||
| MTBF | 250 | kHrs | |||
| Case Size | in | 9.84 x 5.00 x 1.59 | |||
| mm | 250.00 x 127.00 x 40.50 | ||||
| Package Type | Enclosed Module | ||||
| Safety Class | Class I | ||||
| Safety Standards | See Model Selection Guide | ||||
| EMI/EMC Standards | Meets EN 55032 B |
| Model No. | Output V | Output I |
|---|---|---|
| MPE-1500CM-12 | Main - 12 VDC | Main - 125 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-15 | Main - 15 VDC | Main - 100 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-24 | Main - 24 VDC | Main - 62.5 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-27 | Main - 27 VDC | Main - 56 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-36 | Main - 36 VDC | Main - 42 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-48 | Main - 48 VDC | Main - 32 A |
| Aux - 5 VDC | Aux - 2 A | |
| MPE-1500CM-54 | Main - 54 VDC | Main - 28 A |
| Aux - 5 VDC | Aux - 2 A |