| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 5 VDC | 4.5 | 5 | 5.5 | VDC |
| 12 VDC | 10.8 | 12 | 13.2 | VDC | |
| 15 VDC | 13.5 | 15 | 16.5 | VDC | |
| Line Regulation | ±1.5 | % | |||
| Load Regulation | 5 VDC | 8 | 15 | % | |
| 12 VDC | 5 | 10 | |||
| 15 VDC | 4 | 10 | |||
| Short Circuit Protection | Continuous (self-recovery) | ||||
| Isolation Voltage | 60 seconds | 1.5 | kVDC | ||
| Operating Temp Range | -40 | 105 | °C | ||
| MTBF | 3.500 | Mhours | |||
| Case Size | In | 0.531 in x 0.437 in x 0.285 | |||
| mm | 13.5 x 11.1 x 7.25 |
| Model No. | Input | Output V | Output I |
|---|---|---|---|
| ML205S-05B | 5 | 5 | 400 |
| ML205S-12B | 5 | 12 | 167 |
| ML205S-15B | 5 | 15 | 133 |
| ML212S-05B | 12 | 5 | 400 |
| ML212S-12B | 12 | 12 | 167 |
| ML212S-15B | 12 | 15 | 133 |
| ML215S-05B | 15 | 5 | 400 |
| ML215S-12B | 15 | 12 | 167 |
| ML215S-15B | 15 | 15 | 133 |