| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 710/8 | 735/15 | mA | ||
| Input Start Voltage | 18 | VDC | |||
| Output Accuracy | 5% - 100% Load | ±1.0 | ±3.0 | % | |
| Line Regulation | Vin = Min. to Max. @ Full Load | ±0.2 | ±0.5 | % | |
| Load Regulation | 5% - 100% Load | ±0.5 | ±1.0 | % | |
| % | |||||
| Short Circuit Protection | Continuous (Autorecovery) | ||||
| Isolation Voltage | Input - Output | 1500 | VDC | ||
| Operating Temp Range | -40 | 85 | °C | ||
| MTBF | 1,000 | kHrs | |||
| Case Size | In | 1.00 x 1.00 x 0.461 | |||
| mm | 25.4 x 25.4 x 11.70 | ||||
| Case Size With Chassis | In | 2.992 x 1.24 x 0.835 | |||
| mm | 76.00 x 31.50 x 21.20 | ||||
| Case Size With DIN Rail | In | 2.992 x 1.24 x 1.016 | |||
| mm | 76.00 x 31.50 x 25.80 |
| Model No. | Input | Output V | Output I |
|---|---|---|---|
| MI3048S-05CRU | 48 VDC | 5 VDC | 6000 mA |
| MI3048S-12CRU | 48 VDC | 12 VDC | 2500 mA |
| MI3048S-15CRU | 48 VDC | 15 VDC | 2000 mA |
| MI3048S-24CRU | 48 VDC | 24 VDC | 1250 mA |