| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 264 | VAC | ||
| 127 | 370 | VDC | |||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 30 | A Pk | ||
| 230 VAC | 60 | A Pk | |||
| Hold-Up Time | 115 VAC | 20 | mSec | ||
| 230 VAC | 50 | mSec | |||
| Line Regulation | At Rated Load | ±2 | % | ||
| Load Regulation | 0-100% Load, 230 VAC | ±5 | % | ||
| Short Circuit Protection | Continuous (self-recovery) | ||||
| Isolation Voltage | 60 seconds | 3 | kVDC | ||
| Operating Temp Range | -20 | 70 | °C | ||
| MTBF | 0.400 | Mhours | |||
| Case Size | In | 1.61 x 3.94 x 3.62 | |||
| mm | 41.0 x 100 x 92 | ||||
| Safety Class | Class I | ||||
| Safety Standards | UL 62368-1 | ||||
| EMI/EMC Standards | CISPR 32 / EN 55032 |
| Model No. | Output V | Output I |
|---|---|---|
| MDR-60LY-05 | 5 | 10A |
| MDR-60LY-12 | 12 | 5A |
| MDR-60LY-24 | 24 | 2.5A |
| MDR-60LY-48 | 48 | 1.25A |