MDR-40LY

Key Features

  • 40W Output Power
  • 3 kVAC I/O Isolation
  • UL Approved
  • -20°C to 70°C Operation
  • >400 kHour MTBF
  • Meets EN 55032 B
  • Takes AC or DC Input
  • Adjustable DC Output

Datasheet

Additional Tech Info

RoHS CE UK UL
ParameterMinTypMaxUnits
Input Voltage Range90264VAC
127370VDC
Input TypeUniversal
Input Frequency4763Hz
Inrush Current115 VAC30Apk
230 VAC60
Line RegulationAt Rated Load±2.0%
Load Regulation230 VAC 0 - 100% Load±5.0%
Hold-Up Time115 VAC20mSec
230 VAC50
Isolation Voltage3,000VAC
Operating Temp Range-20+70°C
MTBF400kHrs
Case Size3.94 x 1.61 x 3.62
100.0 x 41.0 x 92.0
Package TypeEncapsulated Module
Safety ClassClass II
Safety StandardsUL 62368-1
EMI/EMC StandardsCISPR 32 / EN 55032
Model No.Output VOutput I
MDR-40LY-0556.0 A
MDR-40LY-12123.33 A
MDR-40LY-24241.70 A
MDR-40LY-48480.83 A