MDR-30SY

Key Features

  • 30W Output Power
  • 4 kVAC I/O Isolation
  • UL Approved
  • -20°C to 70°C Operation
  • >900 kHour MTBF
  • Meets EN 55032 B
  • Takes AC or DC Input
  • Adjustable DC Output

Datasheet

Additional Tech Info

ParameterMinTypMaxUnits
Input Voltage Range90264VAC
127370VDC
Input TypeUniversal
Input Frequency4763Hz
Inrush Current115 VAC25Apk
230 VAC45
Line RegulationAt Rated Load±1.0%
Load Regulation0 - 100% Load±1.0%
Hold-Up Time115 VAC12mSec
230 VAC30
Isolation Voltage4,000VAC
Operating Temp Range-20+70°C
MTBF900kHrs
Case Size3.543 x 1.387 x 2.283
90.00 x 35.00 x 58.00
Package TypeDIN-Rail
Safety ClassClass II
Safety StandardsUL 62368-1
EMI/EMC StandardsCISPR 32 / EN 55032
Model No.Output VOutput I
MDR-30SY-055 VDC3.00 A
MDR-30SY-1212 VDC2.50 A
MDR-30SY-1515 VDC2.00 A
MDR-30SY-2424 VDC1.50 A
MDR-30SY-4848 VDC0.63 A