| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 264 | VAC | ||
| 127 | 370 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 25 | Apk | ||
| 230 VAC | 45 | ||||
| Line Regulation | At Rated Load | ±1.0 | % | ||
| Load Regulation | 0 - 100% Load | ±1.0 | % | ||
| Hold-Up Time | 115 VAC | 12 | mSec | ||
| 230 VAC | 30 | ||||
| Isolation Voltage | 4,000 | VAC | |||
| Operating Temp Range | -20 | +70 | °C | ||
| MTBF | 900 | kHrs | |||
| Case Size | 3.543 x 1.387 x 2.283 | ||||
| 90.00 x 35.00 x 58.00 | |||||
| Package Type | DIN-Rail | ||||
| Safety Class | Class II | ||||
| Safety Standards | UL 62368-1 | ||||
| EMI/EMC Standards | CISPR 32 / EN 55032 |
| Model No. | Output V | Output I |
|---|---|---|
| MDR-30SY-05 | 5 VDC | 3.00 A |
| MDR-30SY-12 | 12 VDC | 2.50 A |
| MDR-30SY-15 | 15 VDC | 2.00 A |
| MDR-30SY-24 | 24 VDC | 1.50 A |
| MDR-30SY-48 | 48 VDC | 0.63 A |