MDR-240SIF

Key Features
- 240W Output Power
- 3,000 VAC I/O Isolation
- DIN Rail TS35 (TS-35 (7.5 or 15) Mountable
- Meets UL 61010 & 62368
- Universal 85-264 AC Input
- Very High Efficiency (>90%)
- Meets EN 55032 B
- -40°C to +70°C Operation
- Active PFC
- Compact Metal Case
- Meets LPS (Limited Power Source)
Parameter | Min | Typ | Max | Units | |
Input Voltage Range | 100 | 240 | VAC | ||
AC 85 | 264 370 | ||||
Input Type | Universal | ||||
Input Frequency | 47 | 63 | Hz | ||
Inrush Current | 115 VAC | 15 | APk | ||
230 VAC | 30 | ||||
Line Regulation | ±0.5 | % | |||
Load Regulation | ±1.0 | % | |||
Hold-Up Time, 230VAC | 20 | mSec | |||
Isolation Voltage | 3,000 | VAC | |||
Operating Temp Range | -40 | +70 | °C | ||
MTBF | 300 | kHrs | |||
Case Size (with mount) | 1.26 x 4.33 x 4.88 In | ||||
32.0 x 110.0 x 124.0 mm | |||||
Package Type | DIN Rail | ||||
Safety Standards | Meets UL/cUL 61010, 62368 | ||||
Safety Class | Class II | ||||
Overvoltage Class | Class III (EN 61558) | ||||
EMI/EMC Standards | EN 55032, EN 61000 |
Model No. | Output V | Output I |
MDR-240SIF-12 | 12 VDC | 16.0 A |
MDR-240SIF-24 | 24 VDC | 10.00 A |
MDR-240SIF-48 | 48 VDC | 5.00 A |
MDR-240SIF-55 | 55 VDC | 4.40 A |