MDR-240HY

Key Features

  • 240W Output Power
  • 3 kVAC I/O Isolation
  • UL Approved
  • -25°C to 70°C Operation
  • >150 kHour MTBF
  • Meets EN 55032 B
  • Takes AC or DC Input
  • DC OK Relay Contact

Datasheet

Additional Tech Info

ParameterMinTypMaxUnits
Input Voltage Range90264VAC
127370VDC
Input TypeUniversal
Input Frequency4763Hz
Inrush Current115 VAC33Apk
230 VAC55
Line Regulation±0.5%
Load Regulation±1.0%
Hold-Up Time115 VAC20mSec
230 VAC20
Isolation Voltage3,000VAC
Operating Temp Range-25+70°C
MTBF150kHrs
Case Size4.47 x 2.48 x 4.92
113.5 x 63.0 x 125.0
Package TypeDIN-Rail
Safety ClassClass I
Safety StandardsUL 61010
EMI/EMC StandardsCISPR 32 / EN 55032
Model No.Output VOutput I
MDR-240HY-1212 VDC16 A
MDR-240HY-2424 VDC10 A
MDR-240HY-4848 VDC5 A