MDR-15SP

Key Features

  • 15W Output Power
  • 4,000 VAC I/O Isolation
  • DIN Rail TS35 (7.5 or 15) Mountable
  • Universal 85-264 AC Input
  • Only 17.5 (1 SU) Wide
  • Meets EN 62368
  • Meets EN 55032 B
  • -40°C to +70°C Operation
  • Meets OVC III (EN 61558)
  • Meets LPS (Limited Power Source)
Parameter Min Typ Max Units
 Input Voltage Range 85 264 VAC
 Input Type Universal
 Input Frequency 47 63 Hz
 Inrush Current 115 VAC 15 APk
230 VAC 25
 Line Regulation ±0.5 %
 Load Regulation ±1.0 %
 Hold-Up Time, 115 VAC 230VAC 12 30 mSec
 Isolation Voltage 4,000 VAC
 Operating Temp Range -40 +70 °C
 MTBF 300 kHrs
 Case Size (with mount) 0.68 x 3.54 x 2.28 In
17.5 x 90.0 x 58.0 mm
 Package Type DIN Rail
 Safety Standards Meets UL/cUL 62368
 Safety Class Class II
Overvoltage Class Class III (EN 61558)
 EMI/EMC Standards EN 55032, EN 61000
RoHS UL CE

Datasheet

Additional Tech Info

Safety C of C-EN

CAD Drawing

Model No. Output V Output I
MDR-15SP-05 5.0 VDC 2.40 A
MDR-15SP-12 12 VDC 1.25 A
MDR-15SP-15 15 VDC 1.00 A
MDR-15SP-24 24 VDC 0.63 A
MDR-15SP-48 48 VDC 0.32 A