MDR-150SY

Key Features

  • 150W Output Power
  • 4 kVAC I/O Isolation
  • UL Approved
  • -20°C to 70°C Operation
  • >800 kHour MTBF
  • Meets EN 55032 B
  • Takes AC or DC Input
  • Adjustable DC Output

Datasheet

Additional Tech Info

ParameterMinTypMaxUnits
Input Voltage Range90264VAC
127370VDC
Input TypeUniversal
Input Frequency4763Hz
Inrush Current115 VAC35Apk
230 VAC70
Line RegulationAt Rated Load±1.0%
Load Regulation0 - 100% Load±1.0%
Hold-Up Time115 VAC12mSec
230 VAC30
Isolation Voltage4,000VAC
Operating Temp Range-20+70°C
MTBF800kHrs
Case Size4.13 x 3.543 x 2.30
105.00 x 90.00 x 58.40
Package TypeDIN-Rail
Safety ClassClass II
Safety StandardsUL 62368-1
EMI/EMC StandardsCISPR 32 / EN 55032
Model No.Output VOutput I
MDR-150SY-1212 VDC10.20 A
MDR-150SY-1515 VDC8.55 A
MDR-150SY-2424 VDC5.30 A
MDR-150SY-4848 VDC2.72 A