| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 264 | VAC | ||
| 127 | 370 | VDC | |||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Inrush Current | 115 VAC | 35 | Apk | ||
| 230 VAC | 70 | ||||
| Line Regulation | At Rated Load | ±1.0 | % | ||
| Load Regulation | 230 VAC 0 - 100% Load | ±1.0 | % | ||
| Hold-Up Time | 115/240 VAC | 30 | mSec | ||
| Isolation Voltage | 3,000 | VAC | |||
| Operating Temp Range | -20 | +70 | °C | ||
| MTBF | 800 | kHrs | |||
| Case Size | 3.648 x 2.047 x 2.28 | ||||
| 92.66 x 52.0 x 58.0 | |||||
| Package Type | Encapsulated Module | ||||
| Safety Class | Class II | ||||
| Safety Standards | UL 62368-1 | ||||
| EMI/EMC Standards | CISPR 32 / EN 55032 |
| Model No. | Output V | Output I |
|---|---|---|
| MDR-100SY-12 | 12 | 7.1 A |
| MDR-100SY-15A | 15 | 6.13 A |
| MDR-100SY-15 | 15 | 6.5 A |
| MDR-100SY-24A | 24 | 3.83 A |
| MDR-100SY-24 | 24 | 4.17 A |
| MDR-100SY-48A | 48 | 1.92 A |
| MDR-100SY-48 | 48 | 2.08 A |