MDR-100SP

Key Features
- 100W Output Power
- 4,000 VAC I/O Isolation
- DIN Rail TS35 (7.5 or 15) Mountable
- UL 62368 Approved
- 70 mm (4 SU) Width
- Universal 85-264 AC Input
- Meets EN 55032 B
- -40°C to +70°C Operation
- Meets OVC III (EN 61558)
- Meets LPS (Limited Power Source)
Parameter | Min | Typ | Max | Units | |
Input Voltage Range | 85 | 264 | VAC | ||
Input Type | Universal | ||||
Input Frequency | 47 | 63 | Hz | ||
Inrush Current | 115 VAC | 35 | APk | ||
230 VAC | 70 | ||||
Line Regulation | ±0.5 | % | |||
Load Regulation | ±1.5 | % | |||
Hold-Up Time, 230VAC | 30 | mSec | |||
Isolation Voltage | 4,000 | VAC | |||
Operating Temp Range | -40 | +70 | °C | ||
MTBF | 300 | kHrs | |||
Case Size (with mount) | 2.75 x 3.54 x 2.28 In | ||||
70.0 x 90.0 x 58.0 mm | |||||
Package Type | DIN Rail | ||||
Safety Standards | Meets UL/cUL 62368 | ||||
Safety Class | Class II | ||||
Overvoltage Class | Class III (EN 61558) | ||||
EMI/EMC Standards | EN 55032, EN 61000 |
Model No. | Output V | Output I |
MDR-100SP-12 | 12 VDC | 7.50 A |
MDR-100SP-15 | 15 VDC | 6.50 A |
MDR-100SP-24 | 24 VDC | 4.20 A |
MDR-100SP-48 | 48 VDC | 2.10 A |