MDR-100SP

Key Features

  • 100W Output Power
  • 4,000 VAC I/O Isolation
  • DIN Rail TS35 (7.5 or 15) Mountable
  • UL 62368 Approved
  • 70 mm (4 SU) Width
  • Universal 85-264 AC Input
  • Meets EN 55032 B
  • -40°C to +70°C Operation
  • Meets OVC III (EN 61558)
  • Meets LPS (Limited Power Source)
ParameterMinTypMaxUnits
 Input Voltage Range85 264VAC
    
 Input TypeUniversal
 Input Frequency47 63Hz
 Inrush Current115 VAC 35 APk
230 VAC 70 
 Line Regulation  ±0.5%
 Load Regulation  ±1.5%
 Hold-Up Time, 230VAC 30 mSec
 Isolation Voltage4,000  VAC
 Operating Temp Range-40 +70°C
 MTBF300  kHrs
 Case Size (with mount)2.75 x 3.54 x 2.28 In
70.0 x 90.0 x 58.0 mm
 Package TypeDIN Rail
 Safety StandardsMeets UL/cUL 62368
 Safety ClassClass II
Overvoltage ClassClass III (EN 61558)
 EMI/EMC StandardsEN 55032, EN 61000
RoHS UL CE

Datasheet

Additional Tech Info

Safety C of C-EN

CAD Drawing

Model No.Output VOutput I
MDR-100SP-1212 VDC7.50 A
MDR-100SP-1515 VDC6.50 A
MDR-100SP-2424 VDC4.20 A
MDR-100SP-4848 VDC2.10 A
   