| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 250 | 1500 | VDC | ||
| Transient(30s) | 1700 | ||||
| Output Voltage Accuracy | ±1.0 | ±2.0 | % | ||
| Line Regulation | Rated Load | ±0.5 | % | ||
| Load Regulation | 800 VDC | ±0.5 | % | ||
| Short Circuit Protection | Continuous (Autorecovery) | ||||
| Isolation Voltage | Input - Output | 4000 | VDC | ||
| Operating Temp Range | -40 | +85 | °C | ||
| MTBF | 300 | kHours | |||
| Case Size | In | 4.291 x 2.303 x 1.181 | |||
| mm | 109.00 x 58.50 x 6.00 |
| Model No. | Input | Output V | Output I |
|---|---|---|---|
| MDP4015-12RU | 250 - 1500 VDC | 12 VDC | 3340 mA |
| MDP4015-24RU | 250 - 1500 VDC | 24 VDC | 1670 mA |
| MDP4015-28RU | 250 - 1500 VDC | 28 VDC | 1430 mA |
| MDP4015-48RU | 250 - 1500 VDC | 48 VDC | 833 mA |