| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 5 VDC Input | 4.75 | 5 | 5.25 | VDC |
| 12 VDC Input | 11.4 | 12 | 12.6 | ||
| 24 VDC Input | 22.8 | 24 | 25.2 | ||
| Line Regulation | Input Voltage Variation ±1% | ±0.25 | % | ||
| Load Regulation | 3.3 VDC Output (10-100% Load) | ±3 | % | ||
| Other Output (10-100% Load) | ±2 | % | |||
| Output Voltage Accuracy | Input voltage change ±1% | ±3 | % | ||
| Short Circuit Protection | Continuous (self-recovery) | ||||
| Isolation Voltage | 60 seconds, leakage <1mA | 1.5 | kVDC | ||
| Operating Temp Range | Derating when ≥71°C | -40 | 85 | °C | |
| MTBF | 3.500 | Mhours | |||
| Case Size | In | 0.774 x 0.236 x 0.40 | |||
| mm | 19.65 x 6.00 x 10.16 |
| Model No. | Input | Output V | Output I |
|---|---|---|---|
| MD105S-03CR | 5 VDC | 3.3 VDC | 250 mA |
| MD105S-05CR | 5 VDC | 5 VDC | 200 mA |
| MD105S-09CR | 5 VDC | 9 VDC | 111 mA |
| MD105S-12CR | 5 VDC | 12 VDC | 84 mA |
| MD105S-15CR | 5 VDC | 15 VDC | 67 mA |
| MD105S-24CR | 5 VDC | 24 VDC | 41 mA |
| MD112S-05CR | 12 VDC | 5 VDC | 200 mA |
| MD112S-09CR | 12 VDC | 9 VDC | 111 mA |
| MD112S-12CR | 12 VDC | 12 VDC | 83 mA |
| MD112S-15CR | 12 VDC | 15 VDC | 67 mA |
| MD124S-03CR | 24 VDC | 3.3 VDC | 250 mA |
| MD124S-05CR | 24 VDC | 5 VDC | 200 mA |
| MD124S-09CR | 24 VDC | 9 VDC | 111 mA |
| MD124S-12CR | 24 VDC | 12 VDC | 83 mA |
| MD124S-15CR | 24 VDC | 15 VDC | 67 mA |
* MD105S-05CR, MD105S-12CR, MD112S-05CR have UL/cUL 62368-1 recognition (UL certificate). Contact factory for safety standard status of other models.