MR1011S

MD100SER Datasheet

Key Features

  • 10W Output Power
  • 40 – 160 VDC Input
  • 1,500 VDC Isolation
  • Meets EN 60950
  • Meets EN 50155
  • -40°C to +85°C Operation
  • 1.0 MHr MTBF
  • Compact 1 x 2 In Case
  • Optional Chassis Mount
  • Optional DIN Rail Mount

Datasheet

RoHS CE UK
ParameterMinTypMaxUnits
 Input Voltage Range40110160VDC
 Output Accuracy±1.0±2.0%
 Line Regulation±0.2±0.5%
 Load Regulation±0.5±1.0%
 Short Circuit ProtectionContinuous (Autorecovery)
 Isolation Voltage1,500VDC
 Operating Temp Range-40+85°C
 MTBF1.0MHrs
 Case Size2.0 x 1.0 x 0.465 In
50.8 x 25.4 x 11.8 mm
Model No.InputOutput VOutput I
 MR1011S-03RU40-160 VDC3.3 VDC2400 mA
MR1011S-05RU40-160 VDC5.0 VDC2,000 mA
MR1011S-12RU40-160 VDC12 VDC833 mA
MR1011S-15RU40-160 VDC15 VDC667 mA
MR1011S-24RU40-160 VDC24 VDC416 mA
* For Chassis Mount, Add “-A2” To The Model Number (i.e. MR1011S-15RU-A2) * For DIN Rail Mount, Add “-A4” To The Model Number (i.e. MR1011S-15RU-A4)