MA1200RW
Parameter | Min | Typ | Max | Units |
---|---|---|---|---|
Input Voltage Range | 9 | 12.0 | 18.0 | |
18.0 | 24.0 | 36.0 | VDC | |
36.0 | 48.0 | 72.0 | ||
Output Accuracy | ±1.0 | % | ||
Line Regulation | ±0.5 | % | ||
Load Regulation | ±1.0 | % | ||
Short Circuit Protection | Continuous (Autorecovery) | |||
Isolation Voltage | 1,500 | VDC | ||
Operating Temp Range | -40 | +85 | °C | |
MTBF | 1.0 | MHrs | ||
Case Size | 1.25 x 0.80 x 0.40 In | |||
31.75 x 20.32 x 10.16 mm |
Model No. | Input | Output V | Output I |
---|---|---|---|
MA1212S-02RW | 12 | 2.5 | 2000 |
MA1212S-03RW | 12 | 3.3 | 2000 |
MA1212S-05RW | 12 | 5 | 2000 |
MA1212S-12RW | 12 | 12 | 430 |
MA1212S-15RW | 12 | 15 | 300 |
MA1212D-12RW | 12 | ±12.0 | 200 |
MA1212D-15RW | 12 | ±15.0 | 120 |
MA1224S-02RW | 24 | 2.5 | 2000 |
MA1224S-03RW | 24 | 3.3 | 2000 |
MA1224S-05RW | 24 | 5 | 2000 |
MA1224S-12RW | 24 | 12 | 430 |
MA1224S-15RW | 24 | 15 | 300 |
MA1224D-12RW | 24 | ±12.0 | 200 |
MA1224D-15RW | 24 | ±15.0 | 120 |
MA1248S-02RW | 48 | 2.5 | 2000 |
MA1248S-03RW | 48 | 3.3 | 2000 |
MA1248S-05RW | 48 | 5 | 2000 |
MA1248S-12RW | 48 | 12 | 430 |
MA1248S-15RW | 48 | 15 | 300 |
MA1248D-12RW | 48 | ±12.0 | 200 |
MA1248D-15RW | 48 | ±15.0 | 120 |