| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 264 | VAC | ||
| Input Type | Universal | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Power Factor Correction | Meets EN 61000-3-2 Class D | ||||
| Inrush Current | 115 VAC | 35.0 | APk | ||
| 230 VAC | 70.0 | ||||
| Output Regulation | ±1.0 | % | |||
| Hold-Up Time, 120 VAC | 20 | mSec | |||
| Isolation Voltage | 3,000 | VAC | |||
| Operating Temp Range | 0 | +70 | °C | ||
| MTBF | 100 | kHrs | |||
| Package Type | U-Channel Models | ||||
| Case Size | 6.00 x 4.00 x 1.50 In | ||||
| 152.40 x 101.60 x 38.10 mm | |||||
| Package Type | End Fan "E" Models | ||||
| Case Size | 7.00 x 4.00 x 1.60 In | ||||
| 175.28 x 101.60 x 40.64 mm | |||||
| Package Type | Top Fan "F" Models | ||||
| Case Size | 6.00 x 4.00 x 2.15 In | ||||
| 152.40 x 101.60 x 54.45 mm | |||||
| Safety Standards | EN 60950, UL 60950 | ||||
| EMI/EMC Standards | EN 55022, EN 61000-4 | ||||
| Model No. | Output V | Output I* |
|---|---|---|
| MPU-400S-12yyz | 12 VDC | 33.33 A |
| MPU-400S-24yyz | 24 VDC | 16.67 A |
| MPU-400S-48yyz | 48 VDC | 8.33 A |
| * With 26.85 CFM | ||
| For mechanical configurations | "y" = T for terminal blocks | |
| "y" = A for molex connectors | ||
| "z" = C for Cover | ||
| "z" = E for End Fan | ||
| "z" = F for Top Fan | ||
| "z" = blank for u-channel | ||