MPU-400D

MPU-500AS

Key Features

  • 400W Output Power
  • Universal 90-264V Input
  • EN 60950 Approved
  • Dual Outputs
  • Active PFC to EN 61000
  • End Fan & Top Fan Models
  • Single Output Units Avail.

Datasheet

RoHS CE UK UL
ParameterMinTypMaxUnits
 Input Voltage Range90264VAC
 Input TypeUniversal
 Input Frequency4763Hz
 Power Factor CorrectionMeets EN 61000-3-2 Class D
 Inrush Current, 230 VAC70.0APk
 Output Regulation±1.0%
 Hold-Up Time, 120 VAC16mSec
 Isolation Voltage3,000VAC
 Operating Temp Range0+50°C
 MTBF100kHrs
 Package TypeU-Channel Models
 Case Size6.00 x 4.00 x 1.50 In
152.40 x 101.60 x 38.10 mm
 Package TypeEnd Fan "E" Models
 Case Size7.00 x 4.00 x 1.60 In
175.28 x 101.60 x 40.64 mm
 Package TypeTop Fan "F" Models
 Case Size6.00 x 4.00 x 2.15 In
152.40 x 101.60 x 54.45 mm
 Safety StandardsEN 60950, UL 60950
 EMI/EMC StandardsEN 55022, EN 61000-4
Model No.Output VOutput I
 MPU-400D-0512yz+5.0 VDC30.00A
+12 VDC20.83A
 MPU-400D-0524yz+5.0 VDC30.00A
+24 VDC10.47A
 MPU-400D-0548yz+5.0 VDC30.00A
+24 VDC5.21 A
 MPU-400D-1224yz+12.0 VDC20.83A
+24.0 VDC10.42A
* With 23 CFM
For mechanical configurations “y” = T for terminal blocks “y” = A for molex connectors “z” = blank for U-Channel “I” = I for current share “I” = blank for no current share