| Parameter | Min | Typ | Max | Units | |
|---|---|---|---|---|---|
| Input Voltage Range | 90 | 132 | VAC | ||
| 180 | 264 | ||||
| Input Type | Autoranging | ||||
| Input Frequency | 47 | 63 | Hz | ||
| Power Factor Correction | Meets EN 61000-3-2 | ||||
| Inrush Current | 115 VAC | 35.0 | APk | ||
| 230 VAC | 70.0 | ||||
| Output Regulation | ±5.0 | % | |||
| Hold-Up Time, 110 VAC | 20 | mSec | |||
| Isolation Voltage | 3,000 | VAC | |||
| Operating Temp Range | 0 | +70 | °C | ||
| MTBF | 100 | kHrs | |||
| Package Type | U-Channel Models | ||||
| Case Size | 5.90 x 4.17 x 1.46 IN | ||||
| 150.0 x 106.0 x 37.0 MM | |||||
| Package Type | End Fan "E" Models | ||||
| Case Size | 5.90 x 4.17 x 1.38 IN | ||||
| 127.0 x 82.2 x 35.0 MM | |||||
| Package Type | Top Fan "F" Models | ||||
| Case Size | 5.90 x 4.17 x 1.38 | ||||
| 127.0 x 82.2 x 35.0 MM | |||||
| Safety Standards | EN 60950, UL 60950 | ||||
| EMI/EMC Standards | EN 55022, EN 61000-4 | ||||
| Model No. | Output V | Output I* |
|---|---|---|
| MPU-300D-0512yz | 5 VDC | 30.00A |
| 12 VDC | 16.67A | |
| MPU-300D-0524yz | 5 VDC | 30.00A |
| 24 VDC | 8.33A | |
| MPU-300D-0548yz | 5 VDC | 30.00A |
| 48 VDC | 4.16A | |
| MPU-300D-1224yz | 12 VDC | 16.67A |
| 24 VDC | 8.33A |