MPU-120S

Key Features
- 180W Output Power W/AF
- Universal 90-264V Input
- EN 60950 Approved
- Compact U-Channel
- Meets EN 55022 B
- Five Single Output Models
- 120 kHr MTBF
Datasheet
Additional Tech Info

Parameter | Min | Typ | Max | Units | |
---|---|---|---|---|---|
Input Voltage Range | 90 | 264 | VAC | ||
120 | 370 | VDC | |||
Input Type | Universal | ||||
Input Frequency | 47 | 63 | Hz | ||
Inrush Current | 115 VAC | 30.0 | APk | ||
230 VAC | 60.0 | ||||
Line Regulation | ±1.0 | % | |||
Load Regulation | ±1.0 | % | |||
Hold-Up Time, 115 VAC | 15 | mSec | |||
Isolation Voltage | 4,000 | VAC | |||
Operating Temp Range | -25 | +70 | °C | ||
MTBF | 120 | kHrs | |||
Case Size | 5.16 x 3.24 x 1.50 In | ||||
131.0 x 82.2 x 38.1 mm | |||||
Case Size Other Models | 5.0 x 3.24 x 1.50 In | ||||
127.0 x 82.2 x 38.1 mm | |||||
Package Type | U-Channel | ||||
Safety Standards | EN 60950, UL 60950 | ||||
EMI/EMC Standards | EN 55022, EN 61000-4 |
Model No. | Output V | Output I |
---|---|---|
MPU-120S-05”Y”(C) | 5.0 VDC | 30.00 A ** |
MPU-120S-12”Y” (C) | 12 VDC | 15.00 A * |
MPU-120S-15”Y” (C) | 15 VDC | 12.00 A * |
MPU-120S-24”Y” (C) | 24 VDC | 7.50 A * |
MPU-120S-48”Y” (C) | 48 VDC | 3.75 A * |
** With 30 CFM Airflow
* With 18 CFM Airflow
* “Y” is the connector selection. It is T for Terminal Block, A for Molex or B for clamp