Key Features
- 8W Output Power
- Wide 90 to 305 VAC Input
- EN 60950 Approved
- Meets IEC Safety Class II
- Miniature Case
- -25°C to +70°C Operation
- Meets EN 55022 B
- 350 kHr MTBF
- Single & Dual Outputs
Parameter | Min | Typ | Max | Units | |
Input Voltage Range | 90 | 305 | VAC | ||
120 | 430 | VDC | |||
Input Type | Universal | ||||
Input Frequency | 47 | 440 | Hz | ||
Inrush Current | 115 VAC | 10.0 | APk | ||
230 VAC | 20.0 | ||||
Line Regulation | ±0.2 | % | |||
Load Regulation | ±0.5 | % | |||
Hold-Up Time, 230 VAC | 75 | mSec | |||
Isolation Voltage | 3,000 | VAC | |||
Operating Temp Range | -25 | +70 | °C | ||
MTBF | 350 | kHrs | |||
Case Size | 1.44 x 1.06 x 1.04 In | ||||
36.5 x 27.0 x 26.4 mm | |||||
Package Type | Encapsulated Module | ||||
Safety Class | IEC 60536 Class II | ||||
Safety Standards | EN 60950, UL 60950 | ||||
EMI/EMC Standards | EN 55022, EN 61000-4 |
Parameter | Min | Typ | Max | Units | |
---|---|---|---|---|---|
Input Voltage Range | 90 | 305 | VAC | ||
120 | 430 | VDC | |||
Input Type | Universal | ||||
Input Frequency | 47 | 440 | Hz | ||
Inrush Current | 115 VAC | 10 | APk | ||
230 VAC | 20 | ||||
Line Regulation | ±0.2 | % | |||
Load Regulation | ±0.5 | % | |||
Hold-Up Time, 230 VAC | 75 | mSec | |||
Isolation Voltage | 3,000 | VAC | |||
Operating Temp Range | -25 | 70 | °C | ||
MTBF | 350 | kHrs | |||
Case Size | 1.44 x 1.06 x 1.04 In | ||||
36.5 x 27.0 x 26.4 mm | |||||
Package Type | Encapsulated Module | ||||
Safety Class | IEC 60536 Class II | ||||
Safety Standards | EN 60950, UL 60950 | ||||
EMI/EMC Standards | EN 55022, EN 61000-4 |
Model No. | Output V | Output I |
---|---|---|
MPM-08S-03MB | 3.3 VDC | 2,000 mA |
MPM-08S-05MB | 5.0 VDC | 1,600 mA |
MPM-08S-09MB | 9.0 VDC | 888 mA |
MPM-08S-12MB | 12 VDC | 666 mA |
MPM-08S-15MB | 15 VDC | 533 mA |
MPM-08S-24MB | 24 VDC | 335 mA |
MPM-08D-0503MB | +5/+3.3 VDC | 1,600/310 mA |
MPM-08D-1205MB | +5/+3.3 VDC | 666/100 mA |