Parameter Min Typ Max Units
 Input Voltage Range 9.0 12.0 18.0 VDC
18.0 24.0 36.0
36.0 48.0 75.0
 Output Accuracy   ±5 Vout   ±2.0 ±5.0 %
  Other Vo   ±1.0 ±3.0
 Line Regulation   +VOUT   ±0.2 ±0.5 %
  -VOUT   ±0.5 ±1.0
 Load Regulation   +VOUT   ±0.5 ±1.0 %
  -VOUT   ±0.5 ±1.5
 Short Circuit Protection Continuous (Autorecovery)
 Isolation Voltage 1,500     VDC
 Operating Temp Range -40   +85 °C
 Safety Approvals UL/cUL 60950-1 Recognition
 MTBF 1.0     MHrs
 Case Size 1.0 x 1.0 x 0.461 In
25.4 x 25.4 x 11.7 mm
         
Model No. Input Output V Output I
 MI612S-05ERW 12 VDC 5.0 VDC 1,200 mA
 MI612S-12ERW 12 VDC 12 VDC 500 mA
 MI612D-05ERW 12 VDC ±5 VDC ±600 mA
 MI612D-12ERW 12 VDC ±12 VDC ±250 mA

 MI624S-03ERW 24 VDC 3.3 VDC 1,500 mA
 MI624S-05ERW 24 VDC 5.0 VDC 1,200 mA
 MI624S-09ERW 24 VDC 9.0 VDC 667 mA
 MI624S-12ERW 24 VDC 12 VDC 500 mA
 MI624S-15ERW 24 VDC 15 VDC 400 mA
 MI624S-24ERW 24 VDC 24 VDC 250 mA
 MI624D-05ERW 24 VDC ±5 VDC ±600 mA
 MI624D-12ERW 24 VDC ±12 VDC ±250 mA
 MI624D-15ERW 24 VDC ±15 VDC ±200 mA

 MI648S-03ERW 24 VDC 3.3 VDC 1,500 mA
 MI648S-05ERW 24 VDC 5.0 VDC 1,200 mA
 MI648S-12ERW 24 VDC 12 VDC 500 mA
 MI648S-15ERW 24 VDC 15 VDC 400 mA
 MI648S-24ERW 24 VDC 24 VDC 250 mA
* Dual output units are approved to EN 60950, single output units are not
* For the chassis mount adapter, add "-A2S" to the model no.
* For the DIN rail mount adapter, add "-A4S" to the model no.
       
MI600xERW Downloads: (Click on the picture)
         
Datasheet   E-Book
On-Line
  E-Book
Download
      Filter Modules

Additional Tech Info: (Click on the picture)
    Single Out   Dual   A2S Adapter   A4S Adapter
       
Safety C of C   3D-CAD   3D-CAD   3D-CAD   3D-CAD

Similar Products: (Click on the picture)
MI600ERU   MA600RW   MD600RW   ML600RU    
         
6W 1x1"
4:1 1.5k Iso
  6W DIP
2:1 1.5K Iso
  6W SIP
2:1 1.5k Iso
  6W SMT
4:1 1.5k Iso
   

Many other DC/DC's in this power range are available. contact the factory for more info.