Parameter Min Typ Max Units
 Input Voltage Range 4.5 5.0 5.5 VDC
10.8 12.0 13.2
 Output Accuracy   ±2.0 ±4.0 %
 Line Regulation     ±1.2 %/%Vin
 Load Regulation, 5V Input     ±15 %
 Load Regulation, 12V Input     ±10 %
 Short Circuit Protection Momentary (1.0 Seconds)
 Isolation Voltage 6,000     VDC
 Operating Temp Range -40   +85 °C
 MTBF 3.5     MHrs
 Case Size 1.27 x 0.62 x 0.40 In
32.3 x 15.7 x 10.2 mm
 Safety Standards EN 60950, UL 60950
         
Model No. Input Output V Output I
 A101EHI 5 VDC 5.0 VDC 200 mA
 A102EHI 5 VDC 9.0 VDC 111 mA
 A103EHI 5 VDC 12 VDC 84 mA
 A104EHI 5 VDC 15 VDC 67 mA
 A105EHI 5 VDC ±5 VDC ±100 mA
 A106EHI 5 VDC ±9 VDC ±56 mA
 A107EHI 5 VDC ±12 VDC ±42 mA
 A108EHI 5 VDC ±15 VDC ±33 mA

 A111EHI 12 VDC 5.0 VDC 200 mA
 A112EHI 12 VDC 9.0 VDC 111 mA
 A113EHI 12 VDC 12 VDC 84 mA
 A114EHI 12 VDC 15 VDC 67 mA
 A115EHI 12 VDC ±5 VDC ±100 mA
 A116EHI 12 VDC ±9 VDC ±56 mA
 A117EHI 12 VDC ±12 VDC ±42 mA
 A118EHI 12 VDC ±15 VDC ±33 mA
       
  

Click on the photo to download the full datasheet

 


Click on the photo to download the Safety C of C