Parameter Min Typ Max Units
 Input Voltage Range 90   264 VAC
 Input Type Universal
 Input Frequency 47   63 Hz
 Power Factor Correction Meets EN 61000-3-2 Class D
 Inrush Current 230 VAC     35 APk
 Output Regulation   ±1.0   %
 Hold-Up Time, 120 VAC 20     mSec
 Isolation Voltage 4,000     VAC
 Operating Temp Range 0   +70 °C
 MTBF 100     kHrs
 Case Size 8.00 x 5.00 x 1.60 In
203.20 x 127.00 x 40.64 mm
 Package Type U-Channel
 Safety Standards EN 60950, UL 60950
 EMI/EMC Standards EN 55022, EN 61000-4
         
Model No. Output V Output I*
 MPU-400MS-12yzI 12 VDC 33.33 A
 MPU-400MS-24yzI 24 VDC 16.67 A
 MPU-400MS-48yzI 48 VDC 8.33 A
* With 23 CFM
For mechanical configurations "y" = T for terminal blocks
  "y" = A for molex connectors
  "z" = C for cover
  "z" = blank for U-Channel
  "I" = I for current share
  "I" = blank for no current share
     